Category: BIOASSAY SYSTEM
-
QuantiChrom™ Peroxide Assay Kit | BIOASSAY SYSTEM | DIOX-250
Application For quantitative determination of peroxide and evaluation of drug effects on peroxide metabolism. Key Features Sensitive and accurate. Enhanced color intensity using sorbitol. Detection range 0.2 μM (7 ng/mL) to 30 μM (1,020 ng/mL) H2O2 in 96-well plate assay. Simple and high-throughput. The procedure involves addition of a single detection reagent and incubation for 30 […]
-
QuantiChrom Magnesium Assay Kit | BIOASSAY SYSTEM | DIMG-250
Application For quantitative determination of Mg2+ and evaluation of drug effects on magnesium metabolism. Key Features Sensitive and accurate. Use as little as 5 μL sample. Linear detection range 0.1 mg/dL (41 μM) to 3 mg/dL (1.2 mM) Mg2+ in 96-well plate assay. Simple and high-throughput. The procedure involves addition of two reagents and measuring OD500nm. Can […]
-
Glutathione Assay Kit 250Assay | BIOASSAY SYSTEM | DIGT-250
Application For quantitative determination of reduced glutathione (GSH) and evaluation of drug effects on glutathione metabolism. Key Features Sensitive and accurate. Linear detection range 0.4 – 100 μM in 96-well plate. Simple and convenient. The procedure involves mixing the DTNB Reagent with sample, removing protein precipitates for proteinaceous samples, adding a second Reagent and reading […]
-
QuantiChrom™ G6PDH Assay Kit (100 Assays) | BIOASSAY SYSTEM | DGPDH-100
Application For quantitative colorimetric determination of Glucose-6-Phosphate concentration and evaluation of drug effects on its metabolism. Key Features Fast and sensitive. Linear detection range (20 μL sample): 0.2 to 100 U/L for 15 min reaction. Convenient and high-throughput. Homogeneous “mix-incubate-measure” type assay. Can be readily automated on HTS liquid handling systems for processing thousands of […]
-
Antioxidant Assay Kit | BIOASSAY SYSTEM | DTAC-100
Application For quantitative determination of total antioxidant capacity (TAC) and evaluation of drug effects on TAC metabolism. Key Features Sensitive and accurate. Use 20 μL sample. Linear detection range from 1.5 to 1000 μM Trolox equivalents. Simple and high-throughput. The procedure involves addition of a single working reagent and incubation for 10 min. Can be […]
-
EnzyChrom Triglyceride Assay Kit | BIOASSAY SYSTEM | ETGA-200
Application For quantitative determination of triglyceride and evaluation of drug effects on triglyceride metabolism. Key Features Sensitive and accurate. Use as little as 10 μL samples. Linear detection range 0.01 to 1.0 mmol/L (0.88 to 88.5 mg/dL) triglyceride. Simple and convenient. The procedure involves addition of a single working reagent and incubation for 30 min […]